FireMax200™ Modular Water Heater (Download PDF version)
Model: FM200N™ or FM200L™

| Model Number | BtuH per burner Natural or Propane | Gas Connection | Water Supply | Electrical Connection | Gas Pressure Regulators | Shipping Weight |
| FM200™ | 199,990 | 3/4" NPT | 1" NPT | 120V 1ph 6.2 amps | One each Supplied | 418 lbs |
| Natural Gas Pressure WC @ Inlet | LP Gas Pressure WC @ Inlet | Manifold Pressure WC | Water Pressure (Flow) | Re-circulating Loop | ||||
| Min | Max | Min | Max | Nat | LP | Min | Max | 1" |
| 7” | 10.5” | 10” | 14” | 3.5” | 7.5” | 40 psi | 80 psi | To Storage Tank |
| Clearance From Combustible Surface | Vent Per Local Code | ||
| Side | Top | Rear | Auxiliary Power Vent Required for extended flue lengths Call factory |
6” L - 1” R |
1” | 6” ** | |
| Model/Storage | Temp Rise | 60°F | 70°F | 80°F | 90°F | 100°F | 110°F |
| Output Temp | 110°F | 120°F | 130°F | 140°F | 150°F | 160°F | |
| FireMax200™/120gal | 1 hour | 475 gal | 420 gal | 390 gal | 360 gal | 336 gal | 320 gal |
| 2 hour | 820 gal | 740 gal | 660 gal | 600 gal | 552 gal | 520 gal | |
| Firemax200™/240gal | 1 hour | 600 gal | 540 gal | 510 gal | 480 gal | 456 gal | 440 gal |
| 2 hour | 940 gal | 860 gal | 780 gal | 720 gal | 672 gal | 640 gal | |
*Contact factory if booster will be supplying dishwasher fill valves or tank heat.
**1” from back of exhaust vent
Note: May be vented through the dishwasher canopy or pant-leg exhaust system per 1991 Uniform Mechanical Code Sec 916. & 917. Check with local authority
Water heater shall be a FireMax200™ gas water heater, Model FM200™ as manufactured by Vanguard Technology Inc., Eugene, OR 97402. Water Heater to be fired by a 199,990 Btu infrared power burner, using natural gas or liquid propane fuel, with a woven ceramic fabric element. Burner to be ignited by means of a hot surface igniter and a redundant intermittent pilot light. Heat exchanger to be of heavy duty finned copper tubing and carry a 5 year limited warranty. Standard equipment to include gas pressure regulating valve, internal bronze-stainless re-circulation pump, integrated solid state power control, temperature and pressure relief valve and LED temperature display. Water Heater frame, body panels, and flue collar shall be of all stainless steel construction. Unit shall stand on 6 inch adjustable stainless or composite NSF approved legs. Stainless steel front panel to be removable for access to all components without disconnecting water heater from its installed location. Water Heater to be rated at 88% operating efficiency, minimum. Water heater shall be connected and circulated to one or more hot water storage tanks and controlled by temperature sensors in tank(s).
![]() 29495 Airport Road, Eugene, OR 97402 Tel: 541-461-6020 Fax: 541-461-6023 |
|